EM 100 G2, EM 300 G2, EM 500 G2
08/2004 16/32
3.12 Balanced RF output
voltage at 1kHz
peak deviation
Feed in via XLR socket ––+18dBu and
+6.1V
–
3.13 Unbalanced
RF output voltage
at 1kHz peak
deviation
Feed in via Jack socket ––+12dBu and
+3.0V
–
4Pilot tone
4.1 Pilot tone on RF signal generator at
ANT I: RF level: 1mV
FM1
Deviation: 24kHz
Mod: 1kHz
FM2
Deviation: 2kHz
Mod: 32.768kHz
Pilot tone: “ON“ XLR socket 10dBu
–
4.2 Pilot tone off RF signal generator at
ANT I: RF level: 1mV
FM1
Deviation: 24kHz
Mod: 1kHz
FM2
OFF
See 4.1 XLR socket no signal The display is
red illuminated
5 Monitor module (only EM 500 G2)
5.1 Monitor output
"PHONE"
Reduce deviation from
24kHz to 6kHz.
–––AF segments
1 to 2 bars
5.2 Monitor output
"PHONE"
+12V
DC
at the
DC socket
oscilloscope at the relevant
PHONE connection:
Termination impedances,
32Ω in connector.
Gradually turn monitor control VOL to maxi-
mum, noting the sinus test signal. The signal
must increase cleanly and evenly, without dis-
tortion or drop-out, until it starts to clip.
5.3 Volume control +12V
DC
at the
DC socket
"POWER" = On –– No "scratching"
is heard on
turning and
there is no tone
drop-out.
6 Display module
- The EM 100 G2 exhibits a change in the form of individual segments.
- The EM 300 G2 and EM 500 G2 exhibit consistent changes in color display.
6.1 RF display RF signal at ANT I
Mod: off
RF: 3µV
RF signal at ANT II
Mod: off
RF: 3µV
– EM 100 G2
EM 300 G2,
EM 500 G2
EM 100 G2
EM 300 G2,
EM 500 G2
AF segment, no bar
RF segments 2
± 1 bar
Diversity display I lights up
AF segment not visible
RF segments visible
Diversity display I lights up
AF segment, no bar
RF segments 2
± 1 bar
Diversity display II lights up
AF segment not visible
RF segments visible
Diversity display II lights up
6.2 RF display See 5.1
RF: 20µV
– EM 100 G2
EM 300 G2,
EM 500 G2
RF segment: 4 bars
RF segment: 25dB
6.3 RF display See 5.1
RF: 1mV
– EM 100 G2
EM 300 G2,
EM 500 G2
RF segments:end-scale
deflection
RF segments:end-scale
deflection
6.4 AF display at
nominal deviation
24kHz
Mod: off
– All AF display "0"
6.5 AF display at
nominal deviation
48kHz
Mod: off
– All PEAK
Sequence Type of measure-
ment/adjustment
Signal input Settings Measuring
point/test
point
Required
value
Remarks